Test Items |
Unit |
LCV500S |
Test Standard |
|
Appearance |
- |
Yellow |
Visual |
|
Thickness |
mm |
0.25±0.03 |
ASTM D374/374M |
|
Hardness |
Shore A |
90±5 |
ISO 48-4 |
|
Density |
g/cm³ |
1.5±0.1 |
ASTM D792 |
|
Breaking Force |
N/25mm |
≥100 |
ASTM D5035 |
|
Breakdown Voltage |
KV |
≥4 |
ASTM D149 |
|
Volume Resistivity |
Ω·cm |
≥1×1011 |
ASTM D257 |
|
Dielectric Constant |
1MHz |
3.8~4.3 |
ASTM D150 |
|
Thermal Conductivity |
W/m·K |
5.0±0.3 |
ASTM D5470 |
|
Thermal Impedance |
℃·in²/W |
0.081 |
ASTM D5470 (40psi) |
|
Thermal Impedance |
℃·cm²/W |
0.523 |
ASTM D5470 (40psi) |
|
Flammability |
Grade |
V-0 |
UL94 |
|
Operating Temperature |
℃ |
-50~200 |
- |
Reliable thermal performance starts with the right materials.
With 15 years of expertise, Union Tenda provides thermal interface materials tailored to your applications—from thermal pads and gels to greases, potting compounds and phase change materials. Our in-house R&D and testing capabilities, backed by a 20,000 m² production base, support customers across electronics, AI, EVs and energy storage.
Let's connect to discuss your thermal management needs.

|
Test Items |
Unit |
LCV500S |
Test Standard |
|
Appearance |
- |
Yellow |
Visual |
|
Thickness |
mm |
0.25±0.03 |
ASTM D374/374M |
|
Hardness |
Shore A |
90±5 |
ISO 48-4 |
|
Density |
g/cm³ |
1.5±0.1 |
ASTM D792 |
|
Breaking Force |
N/25mm |
≥100 |
ASTM D5035 |
|
Breakdown Voltage |
KV |
≥4 |
ASTM D149 |
|
Volume Resistivity |
Ω·cm |
≥1×1011 |
ASTM D257 |
|
Dielectric Constant |
1MHz |
3.8~4.3 |
ASTM D150 |
|
Thermal Conductivity |
W/m·K |
5.0±0.3 |
ASTM D5470 |
|
Thermal Impedance |
℃·in²/W |
0.081 |
ASTM D5470 (40psi) |
|
Thermal Impedance |
℃·cm²/W |
0.523 |
ASTM D5470 (40psi) |
|
Flammability |
Grade |
V-0 |
UL94 |
|
Operating Temperature |
℃ |
-50~200 |
- |
Typical Applications
· Thermal interface between chips, processors, storage devices, and heat sinks or enclosures
· Equipment requiring long-term stable cooling, such as base stations and routers
· Thermal interface in automotive electronic control units (ECUs) and battery management systems (BMS)
· Thermal management between power modules and heat sinks
Features and Advantages
· Excellent thermal conductivity and high electrical insulation
· High mechanical strength, wear-resistant, and tear-resistant
· Non-sticky on both sides, making it easy to handle and remove
· Exceptional weather and aging resistance, suitable for long-term use