LCV350S is an electrically insulating thermal interface sheet made from silicone-coated fiberglass fabric. Installed between a heat-generating component and a heat sink or enclosure, it conducts heat across the interface while providing electrical insulation.
LCV350S is a 3.5 W/m·K silicone-coated fiberglass thermal pad with ≥5 kV breakdown voltage. Available in 0.23 and 0.38 mm with custom die cutting.
|
Test Items |
Unit |
LCV350S |
Test Standard |
|
Appearance |
- |
Yellow |
Visual |
|
Thickness |
mm |
0.23/0.38±0.03 |
ASTM D374/374M |
|
Hardness |
Shore A |
90±5 |
ISO 48-4 |
|
Density |
g/cm³ |
1.5±0.1 |
ASTM D792 |
|
Breaking Force |
N/25mm |
≥100 |
ASTM D5035 |
|
Breakdown Voltage |
KV |
≥5 |
ASTM D149 |
|
Volume Resistivity |
Ω·cm |
≥1×1011 |
ASTM D257 |
|
Dielectric Constant |
1MHz |
3.8~4.3 |
ASTM D150 |
|
Thermal Conductivity |
W/m·K |
3.5±0.3 |
ASTM D5470 |
|
Thermal Impedance |
℃·in²/W |
0.088(0.23mm) 0.178(0.38mm) |
ASTM D5470 (40psi) |
|
Thermal Impedance |
℃·cm²/W |
0.568(0.23mm) 1.148(0.38mm) |
ASTM D5470 (40psi) |
|
Flammability |
Grade |
V-0 |
UL94 |
|
Operating Temperature |
℃ |
-50~200 |
- |
Material Features
Fiberglass reinforcement gives the sheet mechanical strength and resistance to wear and tearing.
Non-tacky surfaces on both sides make the sheet easy to position during assembly and remove when needed.
Resistance to weathering and aging supports long-term use.
Computing and storage — Thermal interfaces between chips, processors, or storage devices and their heat sinks or enclosures.
Telecom and networking — Heat transfer within base stations and routers.
Automotive electronics — Thermal interfaces in electronic control units (ECUs) and battery management systems (BMS).
Power electronics — Heat transfer from power modules to heat sinks.
Choose the 0.23 mm or 0.38 mm sheet based on the available clearance at the thermal interface. Custom sheet sizes and die-cut shapes are available to match the mounting footprint.
Reliable thermal performance starts with the right materials.
With 15 years of expertise, Union Tenda provides thermal interface materials tailored to your applications—from thermal pads and gels to greases, potting compounds and phase change materials. Our in-house R&D and testing capabilities, backed by a 20,000 m² production base, support customers across electronics, AI, EVs and energy storage.
Let's connect to discuss your thermal management needs.
|
Test Items |
Unit |
LCV350S |
Test Standard |
|
Appearance |
- |
Yellow |
Visual |
|
Thickness |
mm |
0.23/0.38±0.03 |
ASTM D374/374M |
|
Hardness |
Shore A |
90±5 |
ISO 48-4 |
|
Density |
g/cm³ |
1.5±0.1 |
ASTM D792 |
|
Breaking Force |
N/25mm |
≥100 |
ASTM D5035 |
|
Breakdown Voltage |
KV |
≥5 |
ASTM D149 |
|
Volume Resistivity |
Ω·cm |
≥1×1011 |
ASTM D257 |
|
Dielectric Constant |
1MHz |
3.8~4.3 |
ASTM D150 |
|
Thermal Conductivity |
W/m·K |
3.5±0.3 |
ASTM D5470 |
|
Thermal Impedance |
℃·in²/W |
0.088(0.23mm) 0.178(0.38mm) |
ASTM D5470 (40psi) |
|
Thermal Impedance |
℃·cm²/W |
0.568(0.23mm) 1.148(0.38mm) |
ASTM D5470 (40psi) |
|
Flammability |
Grade |
V-0 |
UL94 |
|
Operating Temperature |
℃ |
-50~200 |
- |
Typical Applications
· Thermal interface between chips, processors, storage devices, and heat sinks or enclosures
· Equipment requiring long-term stable cooling, such as base stations and routers
· Thermal interface in automotive electronic control units (ECUs) and battery management systems (BMS)
· Thermal management between power modules and heat sinks
Features and Advantages
· Excellent thermal conductivity and high electrical insulation
· High mechanical strength, wear-resistant, and tear-resistant
· Non-sticky on both sides, making it easy to handle and remove
· Exceptional weather and aging resistance, suitable for long-term use
Tel:+86-13691979380
+86-19065180554
E-mail:elvinlen@szutd.com
Carly@szutd.com
Address:8th Floor, Tower B, Lechuanghui Building, No. 1211 Guanguang Road, Longhua District, Shenzhen City, Guangdong Province